Digital performance improvements of a CdTe pixel detector for high flux energy-resolved X-ray imaging
2015
Abstract Photon counting detectors with energy resolving capabilities are desired for high flux X-ray imaging. In this work, we present the performance of a pixelated Schottky Al/p-CdTe/Pt detector (4×4) coupled to a custom-designed digital readout electronics for high flux measurements. The detector (4×4×2 mm 3 ) has an anode layout based on an array of 16 pixels with a geometric pitch of 1 mm (pixel size of 0.6 mm). The 4-channel readout electronics is able to continuously digitize and process the signals from each pixel, performing multi-parameter analysis (event arrival time, pulse shape, pulse height, pulse time width, etc.) even at high fluxes and at different throughput and energy re…
High Resolution Spectroscopy ofBΛ12by Electroproduction
2007
An experiment measuring electroproduction of hypernuclei has been performed in Hall A at Jefferson Lab on a $^{12}$C target. In order to increase counting rates and provide unambiguous kaon identification two superconducting septum magnets and a Ring Imaging CHerenkov detector (RICH) were added to the Hall A standard equipment. An unprecedented energy resolution of less than 700 keV FWHM has been achieved. Thus, the observed \lam{12}{B} spectrum shows for the first time identifiable strength in the core-excited region between the ground-state {\it s}-wave $\Lambda$ peak and the 11 MeV {\it p}-wave $\Lambda$ peak.
Radiation damage in zircon
2003
A single, zoned, Sri Lankan zircon exhibits a range of microstructures from crystalline to nearly amorphous that are the result of radiation damage over a dose range of 2.1–10.1·1015 α-decay events/mg (0.16–0.47 dpa). The zones in the crystal were examined at a variety of length scales using optical microscopy, micro-Raman spectroscopy, electron microprobe analysis, and transmission electron microscopy. Birefringence varies linearly with dose: birefringence = −4.71·10−18 /g· D α + 4.86·10−2. Full width at half maximum (FWHM) measurements of the B1g(ν3) peak, as determined by micro-Raman spectroscopy, were used to estimate the extent of radiation damage in each zone. The radiation dose (calc…
A large proportional drift chamber with two-dimensional read-out
1976
Abstract The construction and performance of a large drift chamber are described, which has a sensitive area of 5 m2 and an average chamber thickness of 0.55 × 10−3 radiation lengths. Simultaneous sense wire- and high voltage read-out gives a good time correlation with ajitter of 2.0 ns fwhm. Measurements with a collimated radioactive α-sources resulted in a time resolution of 4.3 ns fwhm corresponding to a space resolution of 0.20 mm fwhm at the sense wire. The space resolution at the high voltage plane is about 25 mm fwhm.
Detector blockbased on arrays of 144 SiPMs and monolithic scintillators: A performane study
2015
[EN] We have developed a detector block composed by a monolithic LYSO scintillator coupled to a custom made 12 12 SiPMs array. The design is mainly focused to applications such as Positron Emission Tomography. The readout electronics is based on 3 identical and scalable Application Specific Integrated Circuits (ASIC). We have determined the main performance of the detector block namely spatial, energy, and time resolution but also the system capability to determine the photon depth of interaction, for different crystal surface treatments. Intrinsic detector spatial resolution values as good as 1.7 mm FWHM and energies of 15% for black painted crystals were measured. & 2014 Elsevier B.V. All…
High performance detector head for PET and PET/MR with continuous crystals and SiPMs
2012
International audience; A high resolution PET detector head for small animal PET applications has been developed. The detector is composed of a 12 mm x 12 mm source continuous LYSO crystal coupled to a 64-channel monolithic SiPM matrix from FBK-irst. Crystal thicknesses of 5 mm and 10 mm have been tested, both yielding an intrinsic spatial resolution around 0.7 mm FWHM with a position determination algorithm that can also provide depth-of-interaction information. The detectors have been tested in a rotating system that makes it possible to acquire tomographic data and reconstruct images of 22Na sources. An image reconstruction method specifically adapted for continuous crystals has been emp…
High Bias Voltage CZT Detectors for High-flux Measurements
2017
In this work, we present the performance of new travelling heater method (THM) grown CZT detectors, recently developed at IMEM-CNR Parma, Italy. Thick planar detectors (3 mm thick) with gold electroless contacts on CZT crystals grown by Redlen Technologies (Victoria BC, Canada) were realized, with a planar cathode covering the detector surface (4.1 x 4.1 mm(2)) and a central anode (2 x 2 mm(2)) surrounded by a guard ring electrode. The detectors, characterized by low leakage currents at room temperature (4.7 nA/cm(2) at 1000 V/cm), allow good room temperature operation even at high bias voltages (> 7000 V/cm). At low rates, the detectors exhibit an energy resolution around 4 % FWIEM at 59.5…
Analysis of the infrared Fourier transform spectrum of the Dyad of 116SnH4
1990
Abstract The FTIR spectrum of monoisotopic 116SnH4 has been recorded with the Bruker 120 HR interferometer at Giessen, West Germany, in the ν 2 ν 4 range extending from 600 to 850 cm−1. The resolution (FWHM) was 2.1 × 10−3 cm−1. The Dyad ν 2 ν 4 (0100, 0001) was analyzed using a sixth-order Hamiltonian. The analysis of infrared transitions enabled us to determine 10 ground state parameters, 9 ν2 parameters, 17 ν4 parameters, and 18 interaction parameters. Of 3800 calculated transitions assigned to observed lines, 1183 unblended lines have been selected for the data refinement. For J ≤ 19, the value of the standard deviation is of the order of magnitude of the estimated experimental accuracy…
Study of the structural changes induced by air oxidation in Ti–Si–N hard coatings.
2008
International audience; 3-μm thick Ti–Si–N coatings were deposited on polished X38CrMoV5 substrates by sputtering a composite Ti–Si target in Ar–N2 reactive mixture. Oxidation tests were performed in air at 700 °C during 2 h. Whatever the silicon content in the range 0–4 at.%, no silicon containing compound was detected by XRD before air oxidation and only the TiN phase was evidenced. The mean grain size estimated from the full width at half maximum of the TiN (111) diffraction peak was close to 10 nm. As commonly reported for Ti–Si–N films, the hardness showed a maximum at 51 GPa versus the Si content. After oxidation of the TiN film, XRD and micro-Raman analyses revealed the occurrence of…
Direct Measurement of Mammographic X-Ray Spectra with a Digital CdTe Detection System
2012
In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP) system, for high-rate X-ray spectroscopy in mammography (1–30 keV). The DPP system performs a height and shape analysis of the detector pulses, sampled and digitized by a 14-bit, 100 MHz ADC. We show the results of the characterization of the detection system both at low and high photon counting rates by using monoenergetic X-ray sources and a nonclinical X-ray tube. The detection system exhibits excellent performance up to 830 kcps with an energy resolution of 4.5% FWHM at 22.1 keV. Direct measurements of clinical molybdenum X-ray spectra were carried out by using a pinhole…